PRTG factory sensor allow us to create a special sensor with
data driven from other sensors.
For example:
I want to calculate (sum) all incoming/outgoing traffic from
all Cisco ASA physical interfaces.
Here are the steps:
1.
Write down all interfaces
sensor ID, it’s listed on the overview tab:
2.
Choose the correct channel
ID for traffic in, out or total and write down the channel ID number (0,-1,1)
3.
Add new sensor to the
device and choose Sensor Factory:
4.
Type the following formula
with the values you have collected in step 1 and 2:
#1:ASA_TOTAL_OUT
Channel(2558,1)+Channel(2560,1)+Channel(2550,1)
|
The sensor I have just created in this example will
calculate sum of traffic out (channel ID value is 1) for all 3 sensors (2558,
2560 and 2550).
There are many operators and formulas we can use for
creating factory sensors, for more information: http://www.paessler.com/manuals/prtg9/sensor_factory_sensor